To prevent overheating, be prepared to replace the failed power supply/cooling module with the new power supply/cooling module immediately.
Removing a Power Supply/Cooling Module

  1. At the rear of the cabinet, press the power switch on the failed power supply/cooling module to the Off position.
  2. Unplug the power cord.
  3. Loosen the captive screw at the top of the latch on the power supply/cooling module that will be replaced.


  4. Push the latch down to disengage the power supply/cooling module from the internal connector.
  5. Slide the power supply/cooling module out of the enclosure.