Type A Power: 2850 Cabinets with 4-Node Cliques and BAR Storage - Data Warehouse Appliances

2850 Platform Product and Site Preparation Guide

Product
Data Warehouse Appliances
Published
February 2018
ft:locale
en-US
ft:lastEdition
2018-04-17
dita:mapPath
ipe1471887155021.ditamap
dita:ditavalPath
2850.ditaval.ditaval
dita:id
ibv1471648709644
Product Category
Hardware

Single-system configuration with one 4-node clique and a BAR tape system.


components loaded/accessible from rearof cabinet no chassis allowedin this space in thiscabinet build unmanaged chassis managed chassis Server Managementchassis ID numbers areon the left. # # KVM Console VMS/Subnet Mgmt (opt) a 1 3 2 Cabinet_1098_301 Secondary SM Ethernet Switch Primary SM Ethernet Switch Network-0 36-Port Switch / Blank No Chassis Allowed No Chassis Allowed No Chassis Allowed No Chassis Allowed No Chassis Allowed Drive Enclosure 0 with Controller Drive Enclosure 1 with ESM Drive Enclosure 0 with Controller i80 Tape Library (optional) i80 Tape Library Drive Enclosure 1 with ESM DB Node DB Node DB Node DB Node Network-1 36-Port Switch / Blank 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 A 26 22 21 20 18 19 17 15 14 13 12 11 10 BAR TMS field install only Channel / ECS / NCS / SAS HPA Worker / TMS / TMSS / Aster 1 / Hadoop 2 (opt) Rack U space numbers Type A Power 1-42 are on the right. first system(4 nodes) chassis installed in Cabinet 1 only Chassis 14 is the System VMS in Cabinet 1, and the Cabinet VMS in other cabinets 1 Aster Appliance 5 2 Appliance for Hadoop 5 or Hadoop 6

Single-system configuration with one 4-node clique and a BAR tape system.


components loaded/accessible from rearof cabinet no chassis allowedin this space in thiscabinet build unmanaged chassis managed chassis Server Managementchassis ID numbers areon the left. # # KVM Console VMS/Subnet Mgmt (opt) No Chassis Allowed field install only a 1 3 2 Cabinet_1103_306 Secondary SM Ethernet Switch Primary SM Ethernet Switch Network-0 36-Port Switch / Blank BAR TMS Drive Enclosure 0 with Controller Drive Enclosure 1 with ESM Drive Enclosure 0 with Controller Drive Enclosure 1 with ESM i80 Tape Library i80 Tape Library Network-1 36-Port Switch / Blank 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 A 26 22 21 18 19 20 17 15 14 DB Node DB Node DB Node DB Node 13 12 11 10 No Chassis Allowed No Chassis Allowed No Chassis Allowed No Chassis Allowed Channel / ECS / NCS / SAS HPA Worker / TMS / TMSS / Aster 1 / Hadoop 2 (opt) Rack U space numbers Type A Power 1-42 are on the right. first system(4 nodes) chassis installed in Cabinet 1 only Chassis 14 is the System VMS in Cabinet 1, and the Cabinet VMS in other cabinets 1 Aster Appliance 5 2 Appliance for Hadoop 5 or Hadoop 6

Single-system configuration with one 4-node clique and a BAR tape system with SKM. This configuration includes a switch at U11.



Single-system configuration with one 4-node clique and a BAR tape system with SKM.



Single-system configuration with one 4-node clique and a BAR tape system with SKM. This configuration includes a switch at U11.



Single-system configuration with one 4-node clique and a BAR tape system with SKM.


KVM Console VMS/Subnet Mgmt (opt) components loaded/accessible from rearof cabinet no chassis allowedin this space in thiscabinet build unmanaged chassis managed chassis Server Managementchassis ID numbers areon the left. # # field install only No Chassis Allowed a 1 2 8 9 10 11 12 13 Cabinet_1122_325 Secondary SM Ethernet Switch Primary SM Ethernet Switch Network-0 36-Port Switch / Blank BAR TMS Drive Enclosure 0 with Controller Drive Enclosure 1 with ESM Drive Enclosure 0 with Controller Drive Enclosure 1 with ESM i80 Tape Library i80 Tape Library Network-1 36-Port Switch / Blank SKM Key Management Server SKM Key Management Server 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 A 26 22 21 20 18 19 17 15 14 DB Node DB Node DB Node DB Node No Chassis Allowed No Chassis Allowed No Chassis Allowed No Chassis Allowed Rack U space numbers Type A Power 1-42 are on the right. chassis installed in Cabinet 1 only Chassis 14 is the System VMS in Cabinet 1, and the Cabinet VMS in other cabinets first system(4 nodes)