Type B, C, D Power: 2850 Cabinets with 2-Node Cliques, 680 Systems, and BAR Storage - Data Warehouse Appliances

2850 Platform Product and Site Preparation Guide

Product
Data Warehouse Appliances
Published
February 2018
ft:locale
en-US
ft:lastEdition
2018-04-17
dita:mapPath
ipe1471887155021.ditamap
dita:ditavalPath
2850.ditaval.ditaval
dita:id
ibv1471648709644
Product Category
Hardware

Multi-system configuration with two systems. The first system includes one 2-node clique, the second system includes one 1-node 680 SMP, and the configuration includes a BAR tape system.


No Chassis Allowed SMP Node 2 3 4 5 6 7 9 13 i80 Tape Library Romley/Legacy BAR TMS Drive Enclosure 0 with Controller Drive Enclosure 0 with Controller Drive Enclosure 1 with ESM a 1 No Chassis Allowed No Chassis Allowed No Chassis Allowed Cabinet_1179_613 Secondary SM Ethernet Switch Primary SM Ethernet Switch Network-0 36-Port Switch / Blank Network-1 36-Port Switch / Blank 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 A 19 18 21 17 15 14 KVM Console VMS/Subnet Mgmt (opt) No Chassis Allowed DB Node DB Node 26 10 11 components loaded/accessible from rearof cabinet no chassis allowedin this space in thiscabinet build unmanaged chassis managed chassis Server Managementchassis ID numbers areon the left. # # Channel / ECS / NCS / SAS HPA Worker / TMS / TMSS / Aster 1 / Hadoop 2 (opt) Channel / ECS / NCS / SAS HPA Worker / TMS / TMSS / Aster 1 / Hadoop 2 (opt) Channel / ECS / NCS / SAS HPA Worker / TMS / TMSS / Aster 1 / Hadoop 2 (opt) Channel / ECS / NCS / SAS HPA Worker / TMS / TMSS / Aster 1 / Hadoop 2 (opt) ) Channel / ECS / NCS / SAS HPA Worker / TMS / TMSS / Aster 1 / Hadoop 2 (opt) Channel / ECS / NCS / SAS HPA Worker / TMS / TMSS / Aster 1 / Hadoop 2 (opt) field install only Type B, C, or D Power Rack U space numbers 1-42 are on the right. chassis installed in Cabinet 1 only Chassis 14 is the System VMS in Cabinet 1, and the Cabinet VMS in other cabinets first system(2 nodes) second system (SMP) 1 Aster Appliance 5 2 Appliance for Hadoop 5 or Hadoop 6

Multi-system configuration with three systems. The first system includes one 2-node clique, the second and third systems each include one 1-node 680 SMP system. The configuration includes a BAR tape system.


No Chassis Allowed SMP Node 2 3 4 5 13 i80 Tape Library BAR TMS Drive Enclosure 0 with Controller Drive Enclosure 0 with Controller Drive Enclosure 0 with Controller Drive Enclosure 1 with ESM a 1 No Chassis Allowed No Chassis Allowed No Chassis Allowed Cabinet_1181_615 Secondary SM Ethernet Switch Primary SM Ethernet Switch Network-0 36-Port Switch / Blank Network-1 36-Port Switch / Blank 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 A 19 18 21 17 15 14 KVM Console VMS/Subnet Mgmt (opt) No Chassis Allowed DB Node DB Node No Chassis Allowed SMP Node 26 10 9 7 6 11 components loaded/accessible from rearof cabinet no chassis allowedin this space in thiscabinet build unmanaged chassis managed chassis Server Managementchassis ID numbers areon the left. # # Channel / ECS / NCS / SAS HPA Worker / TMS / TMSS / Aster 1 / Hadoop 2 (opt) Channel / ECS / NCS / SAS HPA Worker / TMS / TMSS / Aster 1 / Hadoop 2 (opt) Channel / ECS / NCS / SAS HPA Worker / TMS / TMSS / Aster 1 / Hadoop 2 (opt) Channel / ECS / NCS / SAS HPA Worker / TMS / TMSS / Aster 1 / Hadoop 2 (opt) field install only Type B, C, or D Power Rack U space numbers 1-42 are on the right. chassis installed in Cabinet 1 only Chassis 14 is the System VMS in Cabinet 1, and the Cabinet VMS in other cabinets third system (SMP) first system(2 nodes) second system (SMP) 1 Aster Appliance 5 2 Appliance for Hadoop 5 or Hadoop 6

Multi-system configuration with two systems. The first system includes one 2-node clique, the second system includes one 1-node 680 SMP. The configuration includes a BAR tape system with SKM.


No Chassis Allowed SKM Key Management Server SKM Key Management Server 2 3 4 5 13 12 i80 Tape Library BAR TMS Drive Enclosure 1 with ESM Drive Enclosure 0 with Controller Drive Enclosure 0 with Controller a 1 No Chassis Allowed No Chassis Allowed No Chassis Allowed Cabinet_1184_618 Secondary SM Ethernet Switch Primary SM Ethernet Switch Network-0 36-Port Switch / Blank Network-1 36-Port Switch / Blank 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 A 19 18 21 17 15 14 KVM Console VMS/Subnet Mgmt (opt) No Chassis Allowed SMP Node DB Node DB Node 26 10 9 7 6 11 components loaded/accessible from rearof cabinet no chassis allowedin this space in thiscabinet build unmanaged chassis managed chassis Server Managementchassis ID numbers areon the left. # # No Chassis Allowed Channel / ECS / NCS / SAS HPA Worker / TMS / TMSS / Aster 1 / Hadoop 2 (opt) Channel / ECS / NCS / SAS HPA Worker / TMS / TMSS / Aster 1 / Hadoop 2 (opt) Channel / ECS / NCS / SAS HPA Worker / TMS / TMSS / Aster 1 / Hadoop 2 (opt) Channel / ECS / NCS / SAS HPA Worker / TMS / TMSS / Aster 1 / Hadoop 2 (opt) field install only Type B, C, or D Power Rack U space numbers 1-42 are on the right. chassis installed in Cabinet 1 only Chassis 14 is the System VMS in Cabinet 1, and the Cabinet VMS in other cabinets first system(2 nodes) second system (SMP) 1 Aster Appliance 5 2 Appliance for Hadoop 5 or Hadoop 6

Multi-system configuration with three systems. The first system includes one 2-node clique, and the second and third systems each include one 1-node 680 SMP. The configuration includes a BAR tape system with SKM.


Channel / ECS / NCS / SAS HPA Worker / TMS / TMSS / Aster 1 / Hadoop 2 (opt) Channel / ECS / NCS / SAS HPA Worker / TMS / TMSS / Aster 1 / Hadoop 2 (opt) No Chassis Allowed SKM Key Management Server SKM Key Management Server 2 3 4 5 13 i80 Tape Library BAR TMS Drive Enclosure 1 with ESM Drive Enclosure 0 with Controller Drive Enclosure 0 with Controller Drive Enclosure 0 with Controller a 1 No Chassis Allowed No Chassis Allowed No Chassis Allowed Cabinet_1185_619 Secondary SM Ethernet Switch Primary SM Ethernet Switch Network-0 36-Port Switch / Blank Network-1 36-Port Switch / Blank 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 A 19 18 21 17 15 14 KVM Console VMS/Subnet Mgmt (opt) No Chassis Allowed SMP Node DB Node DB Node 26 10 9 7 6 11 No Chassis Allowed SMP Node No Chassis Allowed components loaded/accessible from rearof cabinet no chassis allowedin this space in thiscabinet build unmanaged chassis first system(2 nodes) chassis installed in Cabinet 1 only Chassis 14 is the System VMS in Cabinet 1, and the Cabinet VMS in other cabinets managed chassis Server Managementchassis ID numbers areon the left. second system (SMP) third system (SMP) # # field install only Type B, C, or D Power Rack U space numbers 1-42 are on the right. 1 Aster Appliance 5 2 Appliance for Hadoop 5 or Hadoop 6