Teradata Database Message 5745 - 17.10 - 5745 - Advanced SQL Engine - Teradata Database

Teradata Vantageā„¢ - Database Messages

Product
Advanced SQL Engine
Teradata Database
Release Number
17.10
Release Date
July 2021
Content Type
Programming Reference
Publication ID
B035-1096-171K
Language
English (United States)
Message
PARTITION cannot be determined due to internal error. Please do not resubmit request.
Explanation
A primary (or fallback if an AMP is down) data row has an invalid internal partition number. Therefore, a valid external partition number cannot be returned for the system-derived column PARTITION[#Ln]. Because of this internal error, a snapshot dump is taken and the request is aborted.
Generated By
EVL
For Whom
End user and site support representative.
Notes
None
Remedy
Save a test case and contact your support representative for an analysis of the snapshot dump. Additionally, run CHECKTABLE at level 3 to look for other anomalies in the table and, if any, report them to your support representative.