Teradata Database Message 5669 - 17.10 - 5669 - Advanced SQL Engine - Teradata Database

Teradata Vantageā„¢ - Database Messages

Product
Advanced SQL Engine
Teradata Database
Release Number
17.10
Release Date
July 2021
Content Type
Programming Reference
Publication ID
B035-1096-171K
Language
English (United States)
Message
No restart information found for specified index anlaysis '%VSTR'.
Explanation
There must be an entry in the AnalysisLog table of the specified QCD in case the indicated index analysis must be restarted. This may be due to the following reasons: 1. The SQL INITIATE INDEX ANALYSIS statement did not have any CHECKPOINT clause, hence a RESTART is invalid. 2. The restart record from the AnalysisLog table has been deleted due to some unknown reasons.
Generated By
RES modules.
For Whom
End User.
Notes
None
Remedy
Submit the SQL INITIATE INDEX ANALYSIS statement to restart the analysis Or check the AnalysisLog table to restore the lost record and re-submit the SQL RESTART INITIATE INDEX ANALYSIS statement.