Parallel Database Extensions (PDE) Message 13815 - 17.10 - 13815 - Advanced SQL Engine - Teradata Database

Teradata Vantageā„¢ - Database Messages

Product
Advanced SQL Engine
Teradata Database
Release Number
17.10
Release Date
July 2021
Content Type
Programming Reference
Publication ID
B035-1096-171K
Language
English (United States)
Message
Application not started because all AMPs are in NewProc or Fatal state.
Explanation
Any vproc whose state is NewProc or Fatal cannot be started. Currently, all AMPs are in one or the other of those states. Without AMPs, the database cannot be accessed, so TPA initialization is aborted. PDE is up, but the DBS is not running.
Generated By
PDE Initialization.
For Whom
System Support Representative.
Notes
None
Remedy
If the system is newly installed, or the database is being recreated from scratch, this is normal. Continue with system initialization by running sysinit, config (if needed), and reconfig. as described in the Field Support Guide. If this happens because all vprocs have gone into Fatal state, examine the error log files to see why the vprocs failed. Correct the problem, set the vprocs to Online state with vprocmanager, and force a TPA restart.