Message
Table Rebuild procedures required to recover AMP.
Explanation
A disk read error was encountered while executing a recovery function. The bad data block cannot be rebuilt with the processor on-line. The AMP which detects the error will remain offline. This error is logged prior to a crash due to error ErrAMPRCErrSdown.
Generated By
RbkCtrl.
For Whom
Operator. DBA.
Notes
None
Remedy
Run Table Rebuild to recover the failing table and then restart the Teradata DBS.