Parallel Database Extensions (PDE) Message 13840 - 17.10 - 13840 - Advanced SQL Engine - Teradata Database

Teradata Vantageā„¢ - Database Messages

Product
Advanced SQL Engine
Teradata Database
Release Number
17.10
Release Date
July 2021
Content Type
Programming Reference
Publication ID
B035-1096-171K
Language
English (United States)
Message
Error in startup file: Invalid identifier File: %s line %d Line: %s
Explanation
An error was detected processing one of the PDE startup specification files. The file name and line number where the error occurred are shown, along with the text of the line. The specified vproc type, GDO, partiton or state number is not within the range of values allowed. Vproc types range from 0 to 15. GDO numbers range from 1 to 44. Partition numbers range from 0 to 47. State and substate numbers range from 0 to 255.
Generated By
PDE Initialization.
For Whom
System Support Representative.
Notes
None
Remedy
If the error occurred in the site's own startup specification file in the PDE Configuration directory, correct the error and restart PDE. If the error is in the startup file for one of the Teradata components, contact the Global Support Center for assistance in correcting the problem.