Teradata Database Message 9673 - 17.10 - 9673 - Advanced SQL Engine - Teradata Database

Teradata Vantageā„¢ - Database Messages

Product
Advanced SQL Engine
Teradata Database
Release Number
17.10
Release Date
July 2021
Content Type
Programming Reference
Publication ID
B035-1096-171K
Language
English (United States)
Message
Normalize specification was not copied.
Explanation
This is only a warning to let the user know that Normalize specification will not be copied to the table being created. This is the case where a table name was specified in the Create Table As/Like statement with column names defined in the Create Table clause. For example, CREATE TABLE Table1 (field_1, field_2) Table2 WITH [NO] DATA; Normaliz specification on Table2 (if exist) will not be copied to Table1.
Generated By
Resolver.
For Whom
End User.
Notes
None
Remedy
The message is for information only.