Teradata Database Message 1192 - 17.10 - 1192 - Advanced SQL Engine - Teradata Database

Teradata Vantageā„¢ - Database Messages

Product
Advanced SQL Engine
Teradata Database
Release Number
17.10
Release Date
July 2021
Content Type
Programming Reference
Publication ID
B035-1096-171K
Language
English (United States)
Message
Incremental Restore is not allowed because DBS Internal Control #555 IgnoreIncrementalRestoreState is true. Please run reset_ir_target_system command from DSC before retry running incremental restore.
Explanation
The system has been set to read-write enabled so Incremental Restores are disabled.
Generated By
BAR.
For Whom
End user.
Notes
None.
Remedy
From DSC run the INCREMENTAL RESTORE ALLOW WRITE FOR object_list SQL command to enable all objects for read-write and set the GDO IgnoreIncrementalRestoreState to false.