Parallel Database Extensions (PDE) Message 15069 - 17.10 - 15069 - Advanced SQL Engine - Teradata Database

Teradata Vantageā„¢ - Database Messages

Product
Advanced SQL Engine
Teradata Database
Release Number
17.10
Release Date
July 2021
Content Type
Programming Reference
Publication ID
B035-1096-171K
Language
English (United States)
Message
PDISK %d has incorrect System ID in its tag
Explanation
A mismatch was detected between the system ID contained on the indicated PDISK and the actual system ID as contained in the tvsa_data file. This could occur because the device has not been properly initialized into the system's configuration. If this error is appearing for all devices, it may be because the tvsa_data file (in the TDCONFIG directory) has been corrupted. Because of this error, the pdisk will be marked as inaccessible. This error must be corrected before the device will be used. This may affect one or more AMPs if there is a potential for those AMPs to have data on this device. Please check other events to get all PDISKs, which have incorrect System ID.
Generated By
TVS Node Agent
For Whom
Field Engineer
Notes
None
Remedy
Depending upon the reason, you must fix the cabling, use proper procedures to add storage devices to the system, or restore a good copy of the tvsa_data file.