16.20 - INTERTEST - IBM CICS Interface for Teradata

IBM CICS Interface for Teradata® Reference

prodname
IBM CICS Interface for Teradata
vrm_release
16.20
created_date
October 2018
category
Programming Reference
featnum
B035-2448-106K

In using the INTERTEST diagnostic software from Online Software International with your application, an incorrect wild branch condition or a storage violation may be reported by the diagnostic messages.

These messages indicate that program control branching from a load module occurred or that a storage overwrite condition was attempted (when a call was made to preprocessor or CLI runtime code).

Under INTERTEST 2.5.3, if either condition occurs, your systems support personnel should assemble the INTERTEST program IN25UEX with the parameter CALL=name (name values are defined in the following table) and concatenate the Teradata library CXILOAD to DDname SYSLIB in the link-edit of this INTERTEST program.

For more detailed information, see the customization guide that was supplied with your INTERTEST software.

When debugging under INTERTEST, remember that the user sees none of the code generated by preprocessor or CLI calls.

INTERTEST Name Values 
Environment CALL=name values
Preprocessor1 PRESTB
Preprocessor2 DBCHSTBC, TDARDI
CLIv1 All routines listed in Appendix A of Teradata Call-Level Interface Version 2 Reference for Mainframe-Attached Systems (B035-2417).
CLIv2 DBCHSTBC, TDARDI