TDP0160 TDPNSPCI INCOMPATIBLE WITH HSISXMS - Teradata Director Program

Teradata Director Program (TDP Prefix) Messages

Deployment
VantageCloud
VantageCore
Edition
Enterprise
IntelliFlex
Lake
VMware
Product
Teradata Director Program
Release Number
15.xx, 16.xx, 17.xx, 20.xx
Published
June 2020
Language
English (United States)
Last Update
2023-11-20
lifecycle
Latest
Product Category
Teradata Tools and Utilities

TDP0160 TDPNSPCI INCOMPATIBLE WITH HSISXMS

Explanation:

TDP is ending because the subsystem interface modules (TDPNSPCI and HSISXMS) are at incompatible levels.

Generated By:

TDP.

Notes:

None.

Remedy:

Correct the error with method 1 or method 2: 1. Check for the correct module versions with a different suffix character than used before. Include the correct INITIAL PCSUFX/OSSISUFX command in the TDPPARM data set. Start TDP again. 2. Ensure that the correct modules appear in the PLPA, MLPA, or FLPA. If not, reload the correct modules and re-start TDP.