DISABLE TIME - Teradata Director Program

Teradata® Director Program Reference

Product
Teradata Director Program
Release Number
17.00
Published
June 2020
Language
English (United States)
Last Update
2020-06-18
dita:mapPath
pxm1544831938750.ditamap
dita:ditavalPath
obe1474387269547.ditaval
dita:id
B035-2416
lifecycle
previous
Product Category
Teradata Tools and Utilities

Purpose

Prevents TDP from sending time to the database.

Syntax



Usage Notes

If neither an ENABLE TIME nor a DISABLE TIME command is issued, the deprecated default action specified in the distributed HSISPB is DISABLE. You can use the ENABLE TIME command to enable the option again.

If you are using a Teradata Database release between V1R4.1 and V1R5.1, inclusive, the ENABLE TIME feature is supported only for DBC/1012 configurations controlled by a Model 2 Access Module Processor (AMP) or below. If the configuration at your site does not include a Model 2 AMP, you can include the DISABLE TIME command in the TDPPARM data set to reduce meaningless communication traffic.

For releases prior to V1R4.1 or V1R5.2 and above, ENABLE or DISABLE TIME function as expected.

To set the time, use the RDBMS console command, SET TIME.

Example: DISABLE TIME

DISA TIM

Completion Message

TDP0596 HOST TO DBC TIME MESSAGES ARE: DISABLED