6800 coexistence systems have Mellanox InfiniBand adapters that run BYNET V5. The 6750, 6700, 6690, and 6650 nodes need to be upgraded to BYNET V5 in order to coexist with 6800 nodes. When 6800C or 6800H systems coexist with older generation nodes, the system runs based on the slowest component.
6800H Systems
The following coexistence system configurations are valid for 6800H nodes.
Nodes in System | Add 6800H to a System with 6750H/HX Nodes to Build a Coexistence System | BYNET Version | Compatible BYNET Switch Models |
---|---|---|---|
2-18 | Add 6800H to a system with 6750H/HX nodes. | V5 |
|
19-108 | Add 6800H to a system with 6750H/HX nodes. | V5 |
|
109-162 | Add 6800H to a system with 6750H/HX nodes. | V5 |
|
163-324 | Add 6800H to a system with 6750H/HX nodes. | V5 | Mellanox InfiniBand SX6518 324-port (9107 cabinet) |
325- 648 | Add 6800H to a system with 6750H/HX
nodes. System configurations larger than
324 nodes (to a maximum of 1,024 nodes) are accommodated by
special order.
|
V5 | Mellanox InfiniBand SX6536 648-port (9107 cabinet) |
649-1,024 | Add 6800H to a system with 6750H/HX
nodes. System configurations larger than
324 nodes (to a maximum of 1,024 nodes) are accommodated by
special order.
|
V5 | Two Mellanox InfiniBand SX6536 648-port (two 9107 cabinets) |
Nodes in System | Add 6800H to a System with 6700H Nodes to Build a Coexistence System | BYNET Version | Compatible BYNET Switch Models |
---|---|---|---|
2-18 | Add 6800H to a system with 6700H nodes. | V5 |
|
19-108 | Add 6800H to a system with 6700H nodes. | V5 | Mellanox InfiniBand SX6506-NR 108-port (9107 cabinet) |
109-162 | Add 6800H to a system with 6700H nodes. | V5 |
|
163-324 | Add 6800H to a system with 6700H nodes. | V5 | Mellanox InfiniBand SX6518 324-port (9107 cabinet) |
325- 648 | Add 6800H to a system with 6700H
nodes. System configurations larger than
324 nodes (to a maximum of 1,024 nodes) are accommodated by
special order.
|
V5 | Mellanox InfiniBand SX6536 648-port (9107 cabinet) |
649-1,024 | Add 6800H to a system with 6700H
nodes. System configurations larger than
324 nodes (to a maximum of 1,024 nodes) are accommodated by
special order.
|
V5 | Two Mellanox InfiniBand SX6536 648-port (two 9107 cabinets) |
Nodes in System | Add 6800H to a System with 6690 Nodes to Build a Coexistence System | BYNET Version | Compatible BYNET Switch Models |
---|---|---|---|
2-18 | Add 6800H to a system with 6690 nodes. | V5 |
|
19-108 | Add 6800H to a system with 6690 nodes. | V5 | Mellanox InfiniBand SX6506-NR 108-port (9107 cabinet) |
109-162 | Add 6800H to a system with 6690 nodes. | V5 |
|
163-324 | Add 6800H to a system with 6690 nodes. | V5 | Mellanox InfiniBand SX6518 324-port (9107 cabinet) |
325- 648 | Add 6800H to a system with 6690
nodes. System configurations larger than
324 nodes (to a maximum of 1,024 nodes) are accommodated by
special order.
|
V5 | Mellanox InfiniBand SX6536 648-port (9107 cabinet) |
649-1,024 | Add 6800H to a system with 6690
nodes. System configurations larger than
324 nodes (to a maximum of 1,024 nodes) are accommodated by
special order.
|
V5 | Two Mellanox InfiniBand SX6536 648-port (two 9107 cabinets) |
6800C Systems
The following coexistence system configurations are supported for 6800C nodes:
Nodes in System | Add 6800C to a System with 6700C Nodes to Build a Coexistence System | BYNET Version | Compatible BYNET Switch Models |
---|---|---|---|
2-18 | Add 6800C to a system with 6700C nodes. | V5 |
|
19-108 | Add 6800C to a system with 6700C nodes. | V5 | Mellanox InfiniBand SX6506-NR 108-port (9107 cabinet) |
109-162 | Add 6800C to a system with 6700C nodes. | V5 |
|
163-324 | Add 6800C to a system with 6700C nodes. | V5 | Mellanox InfiniBand SX6518 324-port (9107 cabinet) |
325- 648 | Add 6800C to a system with 6700C
nodes. System configurations larger than
324 nodes (to a maximum of 1,024 nodes) are accommodated by
special order.
|
V5 | Mellanox InfiniBand SX6536 648-port (9107 cabinet) |
649-1,024 | Add 6800C to a system with 6700C
nodes. System configurations larger than
324 nodes (to a maximum of 1,024 nodes) are accommodated by
special order.
|
V5 | Two Mellanox InfiniBand SX6536 648-port (two 9107 cabinets) |
Nodes in Existing System | Add 6800C to a System with 6650C/H Nodes to Build a Coexistence System | BYNET Version | BYNET Switch |
---|---|---|---|
2-18 | Add 6800C to a system with 6650C/H nodes. | V5 |
Switches are installed in the 6800 cabinet or the 9212 cabinet Disable any existing BYA32S switches |
19-108 | Add 6800C to a system with 6650C/H nodes. | V5 | Mellanox InfiniBand SX6506-NR 108-port (9107 cabinet) |
109-162 | Add 6800C to a system with 6650C/H nodes. | V5 |
|
163-324 | Add 6800C to a system with 6650C/H nodes. | V5 | Mellanox InfiniBand SX6518 324-port (9107 cabinet) |
325- 648 | Add 6800C to a system with 6650C/H nodes. | V5 | Mellanox InfiniBand SX6536 648-port (9107 cabinet) |
649-1,024 | Add 6800C to a system with
6650C/H nodes. System configurations larger than
324 nodes (to a maximum of 1,024 nodes) are accommodated by
special order.
|
V5 | Two Mellanox InfiniBand SX6536 648-port (two 9107 cabinets) |