Data loss and/or warranty violation may occur if this procedure is not strictly followed. Accessing or initiating other replacement procedures may cause data loss and loss of warranty coverage.
Wear an anti-static wrist strap attached to an unpainted metal surface on the rack or chassis when handling parts.
Only trained customer personnel should perform this procedure.
  1. If necessary, log on to https://access.teradata.com and initiate an incident.
  2. Obtain a replacement part as described in Obtaining a Replacement Part.
  3. Contact the system administrator if you do not know the host name or IP address of the designated host CMIC (SMWeb 12.06 and later) or SOV-enabled CMIC (SMWeb 12.05 and earlier).
    In SMWeb 12.05 and earlier, you must access the home page of a CMIC that is SOV-enabled. If the CMIC is not SOV-enabled, most web applications and pages are unavailable. If this occurs, you must navigate to the SMWeb home page of an SOV-enabled CMIC. For more information about the SMWeb home page, see SMWeb online help or the Teradata Server Management Web Services User Guide (B035-5350) available at http://www.info.teradata.com.
  4. Remove the new part from its packaging and place it on a static-free surface.
  5. Record the serial number and/or part number of the new part in the site equipment log.
  6. Using a browser, connect to the Server Management Web Services home page by typing the following in the Address field of the browser:
    CMIC Version Home Page Address
    SMWeb 12.06 and later: http://<hostname or IP address of CMIC or Teradata ServiceConnect connection>:9981/CWA/home.asp
    SMWeb 12.05 and earlier: http://<hostname or IP address of SOV-enabled CMIC>:9980/CWA/home.asp
  7. On the Server Management Web Services home page, click Server Management Client.
  8. If prompted, log on to Server Management Client as a Service User. The Server Management Client software opens.
  9. If you have a multi-system configuration, in the Server Management Client Tree View, in the System pull-down menu, select All.


  10. In the Summary Alerts tab, identify the disk array containing the failed power supply:
    1. In the Server Management Client window, click the Summary Alerts tab.
    2. In the Summary Alerts tab, select the summary alert containing the failed power supply.
    3. Click Locate Components.
    The failed disk array appears highlighted in the Server Management Client Tree View.
  11. Verify that the disk array power supply in the Tree View matches the power supply in the summary alert:
    1. In the Tree View, expand the disk array with the failed power supply.
    2. Expand the tray with the failed power supply. indicates a failed power supply.


  12. Open a maintenance window. This prevents alerts from being forwarded to Teradata Customer Support at sites that are TVI-connected.
    1. In the Tree View, select the failed power supply to highlight it.
    2. In the Server Management Client window, select Functions > Maintenance Window.
      A Maintenance Window dialog box appears.


    3. Enter a name for the maintenance window.
    4. Set the Start Time and End Time.
    5. Click Activate.
    6. In the Information dialog box that appears, click Close to acknowledge the maintenance window has been activated.
  13. In the Tree View, select the disk array containing the failed power supply.
  14. Select Functions > Replace FRU.
  15. When the Replace FRU dialog box appears, select Chassis Component, then click OK. The Replace FRU window appears, showing the controller.


  16. Select the Rear tab.
  17. Select the numbered red icon identifying the failed power supply. The FRU Replace Procedure window appears.


  18. At the FRU Replace Procedure window, click Ok to proceed.
  19. Click Ok at the next FRU Replace Procedure window to turn on the locator LEDs.
  20. Verify that the disk array power supply is ready for servicing.
    1. At the rear of the cabinet, open the cabinet door.
    2. Verify the blue Service Action Allowed LED on the power supply/cooling module is illuminated.
      • If the blue Service Action Allowed LED on the target power supply is illuminated, return to the FRU Replace window and click Ok.
      • If the blue Service Action Allowed LED on the target power supply is not illuminated, return to the FRU Replace window and click Cancel.
        If any problems are encountered, notify Teradata Customer Support. Use a contact method that is in accordance with your service contract. If your system is not set up with Automatic Incident Creation (AIC), log on to https://access.teradata.com and initiate or update an incident. If your system is set up with AIC, close the maintenance window and add a comment.