UTY8801 WARNING: Rate Monitoring turned off - macro <databasename> <macroname> does not exist.

Explanation:

Pump assumes the existence of specified macro if the later is not there, then it displays this warning, stops providing information required for monitoring purpose and continues. The database name is "TPumpMacro". The specified macro can be one of the following: (1) ImportCreate (2) ImportRestart (3) LoadUpdateDone (4) LoadUpdateSelect

Generated By:

UTYMSG.

For Whom:

User, who wants to monitor the TPump Utility.

Remedy:

Create the above mentioned macros in the specified database gain access right for the user specified in the logon string in TPump utility.