Teradata Database Message 2839 - 2839 - Analytics Database - Teradata Vantage
Analytics Database Messages
- Deployment
- VantageCloud
- VantageCore
- Edition
- Enterprise
- IntelliFlex
- VMware
- Product
- Analytics Database
- Teradata Vantage
- Release Number
- 15.xx,16.xx,17.xx
- Published
- June 2022
- ft:locale
- en-US
- ft:lastEdition
- 2023-01-05
- dita:mapPath
- sfx1628096178347.ditamap
- dita:ditavalPath
- ft:empty
- dita:id
- B035-1096
- lifecycle
- latest
- Product Category
- Teradata Vantageā¢
- Message
- Invalid attempt to operate on a fallback table.
- Explanation
- An attempt was made to restore a fallback table during an operation other than an all-AMPs restore of an all-AMPs dump.
- Generated By
- Restore.
- For Whom
- End User. Site support representative.
- Notes
- This error may indicate that (a) a user was attempting to add fallback during the restore attempt (which is not valid), or (b) there is an internal error in the Archive Utility software.
- Remedy
- If a concurrent attempt to add fallback is not the problem, identify the tables in the database that are nonfallback, and restore them via individual restore statements. If this fails, Contact your Support Representative.