- Product Category
- Teradata Vantageā¢
- Message
- Table Rebuild procedures required to recover AMP.
- Explanation
- A disk read error was encountered while executing a recovery function. The bad data block cannot be rebuilt with the processor on-line. The AMP which detects the error will remain offline. This error is logged prior to a crash due to error ErrAMPRCErrSdown.
- Generated By
- RbkCtrl.
- For Whom
- Operator. DBA.
- Notes
- None
- Remedy
- Run Table Rebuild to recover the failing table and then restart the Teradata DBS.