Teradata Database Message 6803 - 6803 - Analytics Database - Teradata Vantage

Analytics Database Messages

Deployment
VantageCloud
VantageCore
Edition
Enterprise
IntelliFlex
VMware
Product
Analytics Database
Teradata Vantage
Release Number
15.xx,16.xx,17.xx
Published
June 2022
ft:locale
en-US
ft:lastEdition
2023-01-05
dita:mapPath
sfx1628096178347.ditamap
dita:ditavalPath
ft:empty
dita:id
B035-1096
lifecycle
latest
Product Category
Teradata Vantageā„¢
Message
Invalid hardware architecture for procedure execution.
Explanation
The Teradata RDBMS server Hardware Architecture in which the CALL SQL is submitted is different than the one in which the stored procedure was created. A stored procedure created using 32-bit compiler cannot be executed on 64-bit compiler. This situation can occur if a stored procedure is restored to a different server having different Hardware architecture than the archive was created on.
Generated By
RES modules.
For Whom
End User
Notes
None
Remedy
Recreate the procedure on the new server hardware architecture and resubmit the request.