Teradata Database Message 7671 - 7671 - Analytics Database - Teradata Vantage
Analytics Database Messages
- Deployment
- VantageCloud
- VantageCore
- Edition
- Enterprise
- IntelliFlex
- VMware
- Product
- Analytics Database
- Teradata Vantage
- Release Number
- 15.xx,16.xx,17.xx
- Published
- June 2022
- ft:locale
- en-US
- ft:lastEdition
- 2023-01-05
- dita:mapPath
- sfx1628096178347.ditamap
- dita:ditavalPath
- ft:empty
- dita:id
- B035-1096
- lifecycle
- latest
- Product Category
- Teradata Vantageā¢
- Message
- The log file that saves the spoil information is bad under the directory %VSTR.
- Explanation
- A log file is saved in the node for each database level directory that holds the object code files. This error is logged when the log file is corrupted.
- Generated By
- rtsexecsp
- For Whom
- Field Representative
- Notes
- None
- Remedy
- If the file is corrupted, then the obsolete object code files cannot be deleted. Check if any of the stored procedures or the database itself are non-existant. If so, perform a manual delete operation and remove the bad log file. Note that the clean-up of the obsolete files can no longer be done by the system as long as the bad file exists. The database id can be obtained from the directory name and the SP ID can be obtained along with version number from the object code file name within the database directory.