Teradata Database Message 7813 - 7813 - Analytics Database - Teradata Vantage

Analytics Database Messages

Deployment
VantageCloud
VantageCore
Edition
Enterprise
IntelliFlex
VMware
Product
Analytics Database
Teradata Vantage
Release Number
15.xx,16.xx,17.xx
Published
June 2022
ft:locale
en-US
ft:lastEdition
2023-01-05
dita:mapPath
sfx1628096178347.ditamap
dita:ditavalPath
ft:empty
dita:id
B035-1096
lifecycle
latest
Product Category
Teradata Vantageā„¢
Message
%VSTR.
Explanation
This error indicates that the direction, the state, or the mode of the parameter stream is invalid. Or, the stream has not beeen set up to access attribute values directly.
Generated By
FNC Library
For Whom
UDF application developer
Notes
None
Remedy
Check that the stream's direction, state, and mode are valid for the FNC function being called. Need to open stream with third parameter set to true to be able to call FNC_TblOpGetAttributeByNdx or NC_TblOpSetAttributeByNdx.