Parallel Database Extensions (PDE) Message 11458 - 11458 - Analytics Database - Teradata Vantage
Analytics Database Messages
- Deployment
- VantageCloud
- VantageCore
- Edition
- Enterprise
- IntelliFlex
- VMware
- Product
- Analytics Database
- Teradata Vantage
- Release Number
- 15.xx,16.xx,17.xx
- Published
- June 2022
- ft:locale
- en-US
- ft:lastEdition
- 2023-01-05
- dita:mapPath
- sfx1628096178347.ditamap
- dita:ditavalPath
- ft:empty
- dita:id
- B035-1096
- lifecycle
- latest
- Product Category
- Teradata Vantageā¢
- Message
- GDO file %s is corrupted.
- Explanation
- The specified GDO file appears to be corrupted on all nodes. The checksum in the header and trailer blocks in the file is incorrect, or there some other error occurred while attempting to read the file. This error causes PDE initialization to abort.
- Generated By
- TOS compatibility PDE services.
- For Whom
- System Support Representative.
- Notes
- None
- Remedy
- Examine the file and attempt to determine the cause of the corruption. If possible, restore the file from the backup copy in /var/ns/bkup. Otherwise recreate the file using the appropriate utility, or remove it so that it will be recreated using default values. Then try starting PDE again.