- Teradata Vantageā¢
- Message
- Teradata Channel Driver: error accessing TdTempDir %d, line %d path %s
- Explanation
- The repository for channel diagnostics and logs either does not exist or is write protected. Channel interface is disabled until the problem is corrected. Write access to the diagnostics directory is required for proper functioning of the Teradata Channel Interface.
- Generated By
- PDE channel interface driver.
- For Whom
- System Support Representative.
- Notes
- None
- Remedy
- Ensure that the directory TdTempDir/tchn/data exists and is not write protected.