Parallel Database Extensions (PDE) Message 13809 - 13809 - Analytics Database - Teradata Vantage

Analytics Database Messages

Deployment
VantageCloud
VantageCore
Edition
Enterprise
IntelliFlex
VMware
Product
Analytics Database
Teradata Vantage
Release Number
15.xx,16.xx,17.xx
Published
June 2022
ft:locale
en-US
ft:lastEdition
2023-01-05
dita:mapPath
sfx1628096178347.ditamap
dita:ditavalPath
ft:empty
dita:id
B035-1096
lifecycle
latest
Product Category
Teradata Vantageā„¢
Message
Console timeout.
Explanation
PDE initialization normally waits for the DBS console daemon to start before going on to start any program which might try to communicate with DBW. It timed out waiting for this to happen, which probably means that the console daemon aborted almost immediately after being started.
Generated By
PDE Initialization.
For Whom
System Support Representative.
Notes
PDE initialization continues without waiting for the console to start. The database will come up but DBW probably cannot be used.
Remedy
Check the console and/or error log for a previous message from the cnscim program that indicates the reason for the error. If there is such a message, take appropriate action to correct the problem and force a TPA restart. Otherwise, an operating system shutdown and reboot may clear up the problem.