Parallel Database Extensions (PDE) Message 13810 - 13810 - Analytics Database - Teradata Vantage
Analytics Database Messages
- Deployment
- VantageCloud
- VantageCore
- Edition
- Enterprise
- IntelliFlex
- VMware
- Product
- Analytics Database
- Teradata Vantage
- Release Number
- 15.xx,16.xx,17.xx
- Published
- June 2022
- ft:locale
- en-US
- ft:lastEdition
- 2023-01-05
- dita:mapPath
- sfx1628096178347.ditamap
- dita:ditavalPath
- ft:empty
- dita:id
- B035-1096
- lifecycle
- latest
- Product Category
- Teradata Vantageā¢
- Message
- Vconfig GDO is missing or corrupt.
- Explanation
- The VConfig GDO was missing or empty when PDE initialization was attempted.
- Generated By
- PDE Initialization.
- For Whom
- System Support Representative.
- Notes
- This error aborts PDE initialization; the VConfig GDO is required in order to bring up PDE.
- Remedy
- If this is a new system that has not been configured for Teradata, doing that will correct the problem. If vconfig.gdo is lost on a node of an existing system, copy it from another node, or recreate it from the vconfig.txt file by running the vconfig utility. GDOs can also be recovered from backup copied in the Backup directory.