- %s not started: No Control vproc defined for %s (type %d) vprocs.
- Explanation
- The /tdsw/etc/tpastartup file identifies a program to be started in the control vproc for a given vproc type, but there is no control vproc for that type of vproc. Therefore, the program was not started.
- Generated By
- PDE Initialization.
- For Whom
- System Support Representative.
- Notes
- TPA startup continues, but the TPA may not come up, or may come up with some facility unavailable, depending on which program could not be started.
- Remedy
- Verify that the appropriate vprocs exist and are in runnable states. If all vprocs of the type shown are in fatal state, put them back online with vprocmanager after fixing the problem that made them fatal, and force a TPA restart. In case of doubt, report the problem to the Global Support Center.