Parallel Database Extensions (PDE) Message 15003 - 15003 - Analytics Database - Teradata Vantage

Analytics Database Messages

Deployment
VantageCloud
VantageCore
Edition
Enterprise
IntelliFlex
VMware
Product
Analytics Database
Teradata Vantage
Release Number
15.xx,16.xx,17.xx
Published
June 2022
ft:locale
en-US
ft:lastEdition
2023-01-05
dita:mapPath
sfx1628096178347.ditamap
dita:ditavalPath
ft:empty
dita:id
B035-1096
lifecycle
latest
Product Category
Teradata Vantageā„¢
Message
AMP Vproc %d has been marked FATAL due to an I/O error.
Explanation
The TVS Node Agent has marked the indicated AMP fatal because of a failed device which would potentially need to be accessed by that AMP. This determination is made because the AMP belongs to the same TVS allocation subpool as the failed device. The cause of this device problem must be remedied and a system restart performed before the AMP may be brought back online. Please check other events to get all AMP Vprocs, which are marked FATAL.
Generated By
TVS Node Agent
For Whom
Field Engineer
Notes
None
Remedy
The failed device will be shown in a previous event log. Fix the problem that caused the device failure event, then use vprocmanager to bring the fatal AMP back online.