Parallel Database Extensions (PDE) Message 15053 - 15053 - Analytics Database - Teradata Vantage

Analytics Database Messages

Deployment
VantageCloud
VantageCore
Edition
Enterprise
IntelliFlex
VMware
Product
Analytics Database
Teradata Vantage
Release Number
15.xx,16.xx,17.xx
Published
June 2022
ft:locale
en-US
ft:lastEdition
2023-01-05
dita:mapPath
sfx1628096178347.ditamap
dita:ditavalPath
ft:empty
dita:id
B035-1096
lifecycle
latest
Product Category
Teradata Vantageā„¢
Message
Device prep for TVS not complete for AMP %d unexpected SEG0 version %d
Explanation
This indicates that the TVS preparation step was not properly completed for the amp shown. This should have been done prior to switching to this version of the DBS.
Generated By
TVS Node Agent
For Whom
Field Engineer
Notes
None
Remedy
Back down to the previous release of Teradata. With the database down, start the Filer and run the "upgradetvsa" command. After it completes successfully, switch back to this version of Teradata and try to bring up the TPA. If this error still occurs after performing these steps, contact the Global Support Center.