Message
PDISK %d has a missing or corrupted TVS device tag.
Explanation
The TVS Node Agent has detected a TVS device tag failure on the indicated PDISK. This may affect one or more AMPs if there is a potential for those AMPs to have data on this device. Please check other events to get all PDISKs, which have missing or corrupted TVS device tag.
Generated By
TVS Node Agent
For Whom
Field Engineer
Notes
None
Remedy
If the device is a new device, run the tvsaDeviceInit utility to format the device (or use PUT to do this). If the device is an existing device whose TVS device tag has been corrupted, use the tvsaFixTag utility to place a new tag on the device. WARNING: using tvsaFixTag on a device with any other corruption besides a missing TVS tag can cause other, worse problems. Do not bring up the database on a system where a TVS tag has been manually applied unless you really know what you are doing.