Parallel Database Extensions (PDE) Message 15061 - 15061 - Analytics Database - Teradata Vantage

Analytics Database Messages

Deployment
VantageCloud
VantageCore
Edition
Enterprise
IntelliFlex
VMware
Product
Analytics Database
Teradata Vantage
Release Number
15.xx,16.xx,17.xx
Published
June 2022
ft:locale
en-US
ft:lastEdition
2023-01-05
dita:mapPath
sfx1628096178347.ditamap
dita:ditavalPath
ft:empty
dita:id
B035-1096
lifecycle
latest
Product Category
Teradata Vantageā„¢
Message
Problem mapping pdisks to amps: %s
Explanation
This usually indicates that the vconfig GDO does not agree with the tvsa_vdisk_mapping file. The tvsa_vdisk_mapping file is generated during upgrade to a release of Teradata software containing TVS, and is a snapshot of the PUT-generated tvsa_preferred_mapping file at the time of the upgrade. Pre-TVS disk conversion cannot proceed unless this problem is resolved.
Generated By
TVS Node Agent
For Whom
Field Engineer
Notes
None
Remedy
Upgrades to releases of Teradata containing TVS must not be combined with any vdisk or amp configuration changes. Contact the Global Support Center.