Consider the following limitations before deciding to scale out or scale in.
Considerations | Limitations |
---|---|
Vantage license tier | Developer tier is not supported. |
Maximum node limit | Do not scale out the system beyond the maximum node limit of four times the original node count. |
Maximum volume count per node limit | Do not scale in the system if it increases the volume count beyond 24 per instance. |
Maximum scale out limit | Do not scale out the system beyond the maximum node count limit. You cannot go beyond the minimum storage subpool count of 2 per node. Do not scale out beyond four times the size of a deployed 24-AMPs-per-node system. There are 3 AMPs in a storage subpool. With 24 AMPs per node in an initial system deployment, there are 8 storage subpools per node. |
Minimum scale in limit | Do not scale in the system beyond the maximum storage subpool count of 8 per node. |