TDP3962 MINIMUM: nnnnnnnnn, MAXIMUM: nnnnnnnnn (STATIC|DYNAMIC) - Teradata Director Program

Teradata Director Program (TDP Prefix) Messages

Deployment
VantageCloud
VantageCore
Edition
VMware
Enterprise
IntelliFlex
Lake
Product
Teradata Director Program
Release Number
15.xx, 16.xx, 17.xx, 20.xx
Publication Date
June 2020
Content Type
Messages
Publication ID
B035-1096-TDP
ft:locale
en-US
ft:lastEdition
2023-11-20
ft:sourceId
FTML
lifecycle
Latest
Product Category
Teradata Tools and Utilities

TDP3962 MINIMUM: nnnnnnnnn, MAXIMUM: nnnnnnnnn (STATIC|DYNAMIC)

Explanation:

In response to a TDP 'DISPLAY STORAGE' command, this message follows the TDP3960 message and displays the minimum and maximum number of bytes that may be used for NP I/O, and whether the maximum value was establish by the TDP 'SET STORAGE NP' command (STATIC) or automatically by TDP (DYNAMIC). The minimum value is always calculated by TDP as a function of the number and types of STARTed NPs.

Notes:

Since the usefulness of this information depends upon knowledge of TDP internals, it is intended for use in consultation with Customer Support personnel.

Generated By:

TDP.