Usage Notes - Parallel Data Pump

Teradata® Parallel Data Pump Reference - 17.20

Deployment
VantageCloud
VantageCore
Edition
Enterprise
IntelliFlex
Lake
VMware
Product
Parallel Data Pump
Release Number
17.20
Published
June 2022
ft:locale
en-US
ft:lastEdition
2023-11-17
dita:mapPath
kpf1641281806652.ditamap
dita:ditavalPath
ovd1619195504008.ditaval
dita:id
ouq1478611619316
Product Category
Teradata Tools and Utilities

Once Teradata TPump executes the RUN FILE command, further commands and DML statements are read from the specified source until a LOGOFF command or end-of-file condition is encountered, whichever occurs first. An end-of-file condition automatically causes Teradata TPump to resume reading its commands and DML statements from the previously active source (or the previous RUN source when RUNs are nested), either SYSIN for z/OS, or stdin (normal or redirected) in the UNIX OS. After SYSIN/stdin processes any user-provided invocation parameter, it remains the active input source.

If an end-of-file condition occurs on fileid, SYSIN/stdin is read because there are no more commands or statements in the PARM string.

The command source specified by a RUN FILE command may contain nested RUN FILE commands to 16 levels.

On UNIX systems, an asterisk (*) can be used as the fileid specification for the system console/standard input (stdin) device. The system console is the:
  • Keyboard in interactive mode

    or

  • Standard input device in batch mode