In some cases, simply evaluating the job logs and error tables does not provide enough information to adequately define the required corrective action. In other cases, the corrective action is in place, but the job still does not run correctly. In these cases, Teradata PT provides two additional levels of debugging:

  • Check the values of system resources such as shared memory, processes, semaphores, memory, and so on.

    For example, on Linux, use the following command to get the values:

    • ipcs -lm
    • ipcs -ls
    • ipcs -la
    • ulimit -a
  • Run the job in trace mode
    • tbuild -t -f <filename>
    • Run the operators in your Teradata PT job in trace mode using the TraceLevel attribute.
      TraceLevel = ‘all’
  • Provide truss output (UNIX system only) from the Teradata PT problem component if any of the following errors occurs:
    • IPC Initialization Error (Inter-Process Communication problem)
    • Failed to create Coordinator task
    • Unexpected hanging
  • Use the following steps to get the truss output of the problem component:
    1. ps -ef | grep tbuild (if Coordinator, or Executor).
    2. Find the processid for the problem component.
    3. truss -f -o /tmp/trussout -p <processid>.