Add classification settings to existing utility limits or when creating a utility limit. Classification determines which sessions are associated with a utility limit.
  1. Edit or create a ruleset.
  2. From the ruleset toolbar, click Sessions.
  3. Click the Utility Limits tab.
  4. Select a utility limit or create one.
  5. Click the Classification tab.
  6. Do one of the following:
    • Select a utility type, such as FastLoad or FastExport.
    • Select multiple utility types.
    • Select a specific version, such as TPT Load Operator.
    • Select a combination of utility types and versions.
  7. Click Save.