Example: SCANDISK Output for LSI Interrupted Write in a DB - Analytics Database - Teradata Vantage

Database Utilities

Deployment
VantageCloud
VantageCore
Edition
Enterprise
IntelliFlex
VMware
Product
Analytics Database
Teradata Vantage
Release Number
17.20
Published
June 2022
ft:locale
en-US
ft:lastEdition
2024-05-02
dita:mapPath
ymn1628096214445.ditamap
dita:ditavalPath
qkf1628213546010.ditaval
dita:id
vkz1472241255652
lifecycle
latest
Product Category
Teradata Vantage™

The following is an example of output that SCANDISK generates when it finds an LSI interrupted write pattern in a DB. This error is specific to LSI brand storage.

Ferret ==>
scandisk db
Tue Feb 28, 1995 15:16:50 :Scandisk has been started on all AMP Vprocs in the SCOPE.
vproc  0 (0000)  response
Mon May 06, 2002  15:12:20
1 of 1 vprocs responded with no messages or errors.
Type 'ABORT' to stop the command before completion
Type 'INQUIRE' to check on progress of command
Reading
vproc  0 (0000)  response
Mon May 06, 2002  15:11:11 : CI @ Cylinder 0 7 (0000 000007)
Mon May 06, 2002  15:11:11 : LSI interrupted write pattern found in DB.
0120 MAY 05  05:02:35 LUN 1111, Start Block 00004545, Blocks 0400
Mon May 06, 2002  15:11:11 : rows  -1 (FFFFFFFF) and 0 (0000) are out of order