At startup, messages are displayed to report the startup progress and the Teradata system status. This report includes some recovery process messages as shown here:
H005 Control AMP 001-2 98/02/06 11:35:31 Running DBS Version: 14.00.00.00 98/02/06 11:35:31 Running PDE Version: 14.00.00.00 98/02/06 11:35:32 Current DBS config maps are synchronized (Version: 11) 98/02/06 11:35:32 New DBS config maps are synchronized (Version: 11) 98/02/06 11:35:32 AMP 0000 has been selected as the Control AMP 98/02/06 11:35:33 Initializing DBS Vprocs 98/02/06 11:35:36 Configuration is operational 98/02/06 11:35:36 Starting AMP partitions 98/02/06 11:35:40 Connection accepted 98/02/06 11:36:02 Voting for transaction recovery 98/02/06 11:36:05 Recovery session 1 contains 77 rows on AMP 0000 98/02/06 11:36:16 Starting transaction recovery 98/02/06 11:36:18 Completed transaction recovery 98/02/06 11:36:18 Starting PE partitions 98/02/06 11:37:03 System is operational 98/02/06 11:37:05 Users are logged on 98/02/06 11:37:05 Logons are enabled
The following table lists and explains these and other messages.
Message #... | Means... |
---|---|
1 - AMP mmmm in cluster nnn is back online |
the specified AMP which was offline is now back online. |
2 - AMP mmmm is in offline catchup
|
the AMP is in offline catchup mode. |
3 - AMP mmmm is in online catchup
|
the AMP is in online catchup mode. |
4 - AMP mmmm not brought online for the following reason(s):
|
one of the following:
|
5 - Completed transaction recovery |
Transaction Recovery for online AMPs is compete. |
6 - Recovering down AMPs |
the recovery process is updating tables on AMPs that are in offline catchup. If there was no down AMP in catchup recovery mode, this message is not displayed.
|
7 - Recovery session 1 contains 103 rows on AMP 0001 |
that AMP 0001 has the largest number of rows in the transient journal for the given recovery session. Other AMPs probably have a similar or less rows for the same recovery session. The count reflects how many rows were in the transient journal at the time of the Teradata system restart. It does not necessarily mean a rollback action has to be performed for each row. |
8 - Starting transaction recovery |
transaction recovery has started on online AMPs. |
9 - Startup will wait for recovery to complete |
the user initiated a COLDWAIT restart. |
10 - Voting for transaction recovery |
the application software is determining if there were any incomplete transactions left from the previous operation. Voting is a process by which each AMP examines the transactions that were in process. Any uncompleted transaction will have to be rolled back. |