STATUS DBS ORDERBY CN - Analytics Database - Teradata Vantage

Database Utilities

Deployment
VantageCloud
VantageCore
Edition
Enterprise
IntelliFlex
VMware
Product
Analytics Database
Teradata Vantage
Release Number
17.20
Published
June 2022
ft:locale
en-US
ft:lastEdition
2024-05-02
dita:mapPath
ymn1628096214445.ditamap
dita:ditavalPath
qkf1628213546010.ditaval
dita:id
vkz1472241255652
lifecycle
latest
Product Category
Teradata Vantageā„¢

The STATUS DBS ORDERBY CN command reports the status of Online and NotOnline Vantage AMP vprocs, optionally ordered by cluster number.

Syntax

{ STATUS | ST } DBS [ ORDERBY CN ]

Usage Notes

The STATUS DBS Orderby CN command returns the Online and NotOnline Vantage AMP vprocs ordered by the cluster status tables only. When applicable, a footnote will follow the Database Status Table, indicating which AMP vproc has been selected as the Control AMP.

ONLINE vproc Columns
Column Description
Vproc-Ids Range Uniquely identifies the Vproc-id or Vproc-ids individually or in a range across the entire system. Vproc numbers in the range of 0 through 30719 are used exclusively by the Vantage configuration. Vproc numbers greater than 30719 are used exclusively by PDE and are not included in the Teradata logical configuration.
Crash Count Represents the number of times the vproc has crashed.
CN No. Displays the cluster number for the AMP as defined during a system configuration or reconfiguration. The valid range of cluster numbers is 0 to 8099.
NOTONLINE vproc Columns
Column Description
Vproc-Ids Range Uniquely identifies the Vproc-id or Vproc-ids individually or in a range across the entire system. Vproc numbers in the range of 0 through 30719 are used exclusively by the Vantage configuration. Vproc numbers greater than 30719 are used exclusively by PDE and are not included in the Teradata logical configuration.
Crash Count Represents the number of times the vproc has crashed.
Vproc State Represents the current PDE system state of a vproc if the state is not online.
Config Status Displays the Teradata Logical Configuration Map Status of a vproc.
Cluster Number Displays the cluster number for the AMP as defined during a system configuration or reconfiguration. The valid range of cluster numbers is 0 to 8099.

Example: Displaying a cluster-ordered list of AMP status

Enter a command, HELP or QUIT:
status dbs orderby cn

SYSTEM NAME: ippd        
                          DBS LOGICAL CONFIGURATION
                          -------------------------

ONLINE AMP Vprocs ordered by Cluster No. -
Vproc-Ids                  Crash  CN     Vproc-Ids                  Crash  CN
Range                       Cnt   NO     Range                       Cnt   NO
--------------------------  ---  ----    --------------------------  ---  ----
0*-1                         0      0    2-3                          0      1
4-5                          0      2    6-7                          0      3
-------------------------------------------------------------------------------
*   DBS Control AMP

  DBS State: Logons are enabled - Users are logged on

  DBS RestartKind: COLD