BCMGR-4833 HLS scan-deploy persists references with empty parentName and childName fields, causing the dictionary encoder invariant check to fail and resulting in a failed deploy operation.
BCMGR-4807 A false-positive Critical Alert 7 (ALERT_INVALID_PARCEL) triggers repeatedly on Business Continuity Manager cold start due to redundant control messages.
BCMGR-4800 On standby systems, COLLECT STATISTICS uses ACCESS lock semantics and can run before a concurrent INSERT completes, collecting statistics on empty tables and causing query performance degradation.
BCMGR-4755 The endpoint process becomes unresponsive after repeated TLS handshake failures due to file descriptor leaks.
BCMGR-4737 A format string vulnerability in processMgmtCommand can cause the sequencer to crash when special characters are passed in bcmadmin commands.
BCMGR-4701 Session list sorting by Username and Routing Rule does not default to ascending order.
BCMGR-4649 TD_UNPIVOT table operator queries fail to parse through Business Continuity Manager, returning a syntax error.
BCMGR-4582 After system activation, Business Continuity Manager waits for the full AccountStringScanFreq interval before reading account strings, causing logons to match incorrect routing rules during that window.
BCMGR-4547 The promoted sequencer does not read systemsList.json during takeover, which causes loss of OOS and frozen system status after failover.
BCMGR-4424 MDM deployment on Business Continuity Manager fails when executing REPLACE VIEW statements due to dictionary object lookup issues, returning error 3807.
BCMGR-4418 Tightened file permissions cause customer-reported world-writable Business Continuity Manager application files to be flagged during security hardening.
BCMGR-3949 A memory allocation error appears in logs when CollectStatsPostResync is enabled and resync runs after a table is dropped from the active system.
BCMGR-2962 During ROS Mload recovery (single and multi-table), objects can remain in an interrupted or unrecoverable state.
BCMGR-2918 Alert 260 uses the term "SLA Exceeded," which implies a contractual service-level agreement even though it only represents a table synchronization threshold being exceeded. It is now renamed to "Resync Threshold Exceeded."
BCMGR-2444 On the standby server, the SYSTEM STATUS command incorrectly reports all systems as disconnected.
BCMGR-2398 ROS Mload abort handling for scenarios, including TPA reset, process kills, space issues, and system interrupts, leave tables in an interrupted or unrecoverable state.