| Reference | Description |
|---|---|
| BCMGR-4800 | When INSERT statements in one session are followed by a COLLECT STATISTICS or DROP STATISTICS statement on the same target table in a separate session, the standby system may execute the statements concurrently. As a result, statistics may be collected against an incomplete or empty table, leading to degraded query performance. This can occur even when the original sessions are several minutes apart. This behavior occurs because strict locking control is not enforced for these SQL statements. Workaround: Use one of the following approaches when issuing COLLECT STATISTICS or DROP STATISTICS statements:
|
| BCMGR-4758 | When you run the addUnityMgmtUser.sh script for the standby system, the active system is disconnected unexpectedly. This occurs when the standby system is deactivated, the Unity management password is set, and the script is executed sequentially against both Teradata systems. Workaround: None. |
| BCMGR-4718 | Queue table operations sometimes enter a perpetual state. This occurs when Business Continuity Manager-managed sessions encounter an undetected deadlock condition involving queue tables. Under Business Continuity Manager replication, the deadlock detection mechanism does not trigger, which causes the inserting session to remain blocked and the consuming session to wait indefinitely. Workaround: None. |
| BCMGR-4717 | The SQL workloads routed through the BCM router intermittently fail with Failure 3807 Object not found. The issue persists even after system-level scans and database activation. Workaround: None. |
| BCMGR-4715 | When the target database is empty and you run MODIFY DATABASE <db> AS PERMANENT from a Business Continuity Manager machine, the operation fails with Failure 3807 Object not found. Workaround: Avoid operating on an empty database through Business Continuity Manager. Create at least one object, run a dictionary scan, and then run the MODIFY DATABASE <db> AS PERMANENT command. Alternatively, set the permanent space at database creation time. |
| BCMGR-4425 | When you attempt to create a volatile table that contains non-deterministic query constructs, the operation fails with Error 4529: Request rejected due to object/system state. Workaround: None. |
| BCMGR-4289 | The Business Continuity Manager provisioning process does not automatically configure the eth1 network interface with customer-facing IP addresses. As a result, Business Continuity Manager instances do not have network connectivity after deployment and require manual network configuration. Workaround: Manually configure the eth1 interface on the affected instance. Contact the Teradata Account team for detailed instructions. |