Purpose

Lists all alerts and type IDs for ENABLE or DISABLE commands.

Syntax

ALERT LIST TYPES ;

Example

bcmadmin>  ALERT LIST TYPES; 
----------------------------------------------
The following alerts are defined
Alert Type         : 1
Alert Description  : BCM sequencer has started
Alert Category     : System
Alert Severity     : Normal
Alert Status       : Enabled
Recommended Action : Normal system operation. Alert must be manually cleared.
----------------------------------------------
Alert Type         : 2
Alert Description  : An error has prevented a BCM process from starting. See log for details
Alert Category     : System
Alert Severity     : Critical
Alert Status       : Enabled
Recommended Action : Correct the error and start the process again.
----------------------------------------------
The output displays in this format.
Label Description
Alert Type The alert number for this alert. Used when marking alerts as enabled or disabled.
Alert Description A general description.
Alert Category Which category/part of Business Continuity Manager the alert belongs to.
Alert Severity The severity of the alert (Normal, Warning, Critical).
Alert Status Enabled or disabled.
Recommended Action A default recommended action. This can be updated.