BAR Setup Portlet | IR Support | Teradata DSA - BAR Setup Portlet: IR Support - BAR - Data Stream Architecture

Teradata® DSA User Guide

Deployment
VantageCloud
VantageCore
Edition
Enterprise
IntelliFlex
VMware
Product
BAR
Data Stream Architecture
Release Number
17.20
Published
November 2022
Language
English (United States)
Last Update
2023-11-30
dita:mapPath
bis1632417576364.ditamap
dita:ditavalPath
vwp1576617377804.ditaval
dita:id
cyv1467242268519
Product Category
Software
Teradata Tools and Utilities

The BAR Setup portlet has a new section for IR support. Refer to these definitions if you need to use these options.

From the BAR Setup portlet, select your DSC server, Systems and Nodes, your system, then IR Support.

Option Description
Cleanup Logging Level Level of BAR log information to display for cleanup. Extensive logging information is typically only useful for support personnel when gathering information about a reported problem.
Error
Default. Enables minimal logging. Provides only error messages.
Warning
Adds warning messages to error message logging.
Info
Adds informational messages to warning and error message logging.
Debug
Full logging. All messages, including debug, are sent to the job log.
This setting can affect performance.
Cleanup Time Out Time out value in minutes. Ends the current request as Failed, allowing a new request to be submitted. Default: 720
Cleanup the source system for incremental restore Select Cleanup to delete the deleted rows logging subtables on the system after the system has been disabled for incremental restore.
Get Cleanup status Provides status on the current cleanup process.
Reset Logging Level Level of BAR log information to display for reset. Extensive logging information is typically only useful for support personnel when gathering information about a reported problem.
Error
Default. Enables minimal logging. Provides only error messages.
Warning
Adds warning messages to error message logging.
Info
Adds informational messages to warning and error message logging.
Debug
Full logging. All messages, including debug, are sent to the job log.
This setting can affect performance.
Reset Time Out Time out value in minutes. Ends the current request as Failed, allowing a new request to be submitted. Default: 720
Reset the target system for incremental restore Resets the target system to allow incremental restore again.
Important: All existing incremental restore jobs are forced to run as full restore for their next run.
Get Reset status Provides progress on the reset to incremental restore.