Security hardening restricts access to certain ports on the Analytics Database node, which can cause problems when trying to perform a migration to the system.

The message BYPASS_AR_MONITOR CNS connect timeout indicates a failure to connect to the CNS subsystem on the cnshost control node.

If this occurs during a migration, it is likely that access to port 3015 is restricted. To correct the problem, reopen port 3015 because it is needed to perform the migration.

For more information, see Teradata® VantageCloud Enterprise on AWS (DIY) Installation and Administration Guide, B035-2800.