The following table provides a listing of TWM 5.4.6 dependency issues. These are Teradata, Client/ODBC, or Microsoft issues. Some are fixed, but listed here for users who may have older versions of TWM and might also encounter these problems.
Reference Number | Product | Description |
---|---|---|
TWM-979 | V14.00.00, V14.10.00 | PMML Scoring does not work on TD 14.0, 14.10, 15.0, 15.10 or 16.00 systems running on SLES11. The error received from Teradata is “Operation Error computing expression involving table.column.” The issue does not occur on Teradata running on SLES10. A workaround for this issue on SLES11 is to alter both the NormContinuous and NormContinuousMV functions to execute protected. This is accomplished with “ALTER FUNCTION database.functionname EXECUTE PROTECTED.” |