15.00 - 6993 The sample column %VSTR does not match the table's definition. - Teradata Database

Teradata Database Messages

Product
Teradata Database
Release Number
15.00
Content Type
Programming Reference
Publication ID
B035-1096-015K
Language
English (United States)

6993 The sample column %VSTR does not match the table's definition.

Explanation:

Random AMP sample emulation cannot be set if the value of the NumIndexes and Fields[0] thru Fields[NumIndexes-1] columns in the SystemFE.Opt_RAS_Table do not match the number of indexes on the table and the number of fields that comprise each index respectively as defined in the Data Dictionary.

Generated By:

OPT modules.

For Whom:

End User.

Remedy:

Re-export the random AMP samples from the target system or change the table's definition on the test system to match that of the target system.