15.00 - 2714 Resusage discarded some monitoring information because of insufficient resources %s - Teradata Database

Teradata Database Messages

Product
Teradata Database
Release Number
15.00
Content Type
Programming Reference
Publication ID
B035-1096-015K
Language
English (United States)

2714 Resusage discarded some monitoring information because of insufficient resources %s

Explanation:

ResUsage software was not able to keep up with its workload, as described in the message. This usually happens because the system is too busy to handle the resusage log rate specified in the control GDO.

Generated By:

SSSRSS -- resource usage monitoring.

For Whom:

System Administrator, System Support Representative.

Notes:

This event is informational.

Remedy:

Consider setting longer resusage collect and log intervals or disabling one or more ResUsage tables. If this is infeasible or the explanation does not seem to fit your case, contact your Support Representative.