6803 Invalid hardware architecture for procedure execution.

Explanation:

The Teradata RDBMS server Hardware Architecture in which the CALL SQL is submitted is different than the one in which the stored procedure was created. A stored procedure created using 32-bit compiler cannot be executed on 64-bit compiler. This situation can occur if a stored procedure is restored to a different server having different Hardware architecture than the archive was created on.

Generated By:

RES modules.

For Whom:

End User

Remedy:

Recreate the procedure on the new server hardware architecture and resubmit the request.