15.00 - 2865 Data corruption detected in %DBID.%TVMID. - Teradata Database

Teradata Database Messages

Product
Teradata Database
Release Number
15.00
Language
English (United States)
Last Update
2018-09-24

2865 Data corruption detected in %DBID.%TVMID.

Explanation:

The current request was aborted because the Teradata DBS detected internal inconsistencies in the table.

Generated By:

AMP Software.

For Whom:

End User.

Notes:

This may be the result of an operational error during recovery (Restore, Rollback or Rollforward) or the result of a software problem. Often, another error (such as ErrAMPDupFBRId, ErrAMPMissFBRow, ErrAMPRowNotIdx or ErrAMPRowIdx) is logged on the Teradata DBS console which contains more information about the nature of the data corruption.

Remedy:

If the table has been the target of improper recovery operations, restore the table or drop and recreate it. If the table has not been the target of improper recovery operations, contact your Support Representative.