2861 Data inconsistency detected - Fallback rowid already in use

Explanation:

This error is logged when an AMP attempts to insert a fallback row and the rowid is already in use.

Generated By:

AMP Steps.

For Whom:

DBA Site support representative

Notes:

This may be the result of an operational error during recovery (Restore, Rollback or Rollforward) or the result of a software problem. Additional information is logged to identify the table and row in error. This often is accompanied by a ErrAMPDataCorr error being returned in response to a user request.

Remedy:

If the table has been the target of improper recovery operations, restore the table or drop and recreate it. If the table has not been the target of improper recovery operations, contact your Support Representative.